Cooling and power control
Data Centers
Cooling that adjusts itself every minute.
Less power spent on cooling, and more of your grid connection left for IT.
What changes in your facility
- 57%
- of their grid connection that smaller colocation sites use, averaged over a year International Energy Agency, 2026, citing EPRI
- 1.54
- average power usage effectiveness in 2025, the sixth year it has barely moved Uptime Institute, 2025
- 1 in 5
- serious outages cost more than $1 million Uptime Institute, 2025
- 11×
- rise in the power density of AI servers, 2020 to 2025 International Energy Agency, 2026
- More IT load on the grid connection you have
- Power, not floor space, is what limits growth now. Every kilowatt the cooling plant no longer needs is one your IT can use.
- Less power spent on cooling
- Setpoints tuned once at commissioning cool for the worst day, every day. Moving them with the load and the weather keeps servers inside their limits for less.
- Fewer outages that start in the building
- Power problems remain the top cause of serious outages. A chiller that starts short-cycling, or a setpoint left behind after a service visit, shows up the same day instead of at the next audit.
- Control that keeps up with AI loads
- AI racks draw far more power, and their heat changes faster. Cooling has to answer in minutes, not at the next shift change.
Where the cooling energy goes
The IT load is given. Everything spent moving its heat out of the building is overhead, and most of that overhead sits in setpoints that were tuned once, at commissioning, with a margin to be safe.
Heat leaves a data hall through a chain: server fans into the cold aisle, CRAH or CRAC units, the chilled water loop, the chillers, and the cooling towers or dry coolers outside. Each stage has its own setpoint: supply air temperature and fan speed, chilled water supply temperature, condenser water approach, and the point at which the economizer takes over. Each was set with a margin, and the margins add up to air delivered colder than any server needs, water colder than the coils need, and free-cooling hours left unused on days the weather would have given them away.
The load underneath those setpoints moves every hour and the weather moves every day. Holding the setpoints still is what turns a safety margin into a permanent energy cost. What actually constrains you is the air the servers will accept, temperature and humidity together, and that is a range rather than a single number.
Where the margin sits
The saving is the distance between the warmest air the servers accept and where the setpoints sit today, and it is paid every hour the two are apart.
How KoPilot runs the cooling plant
KoPilot is built around the facility's own equipment, operating limits and control architecture, and it leaves the building management system in charge of the equipment.
- Physics-informed models
- Of cooling and airflow, built for this facility rather than a facility of this type.
- Continuous optimization
- Of operating setpoints, as IT load and outdoor conditions change.
- Equipment and thermal constraints
- The limits the optimization is not allowed to cross.
- Supervisory controls
- That define what the system can and cannot change.
- Monitoring and fallback
- So the facility keeps running safely if anything upstream stops.
Start with the operational data
Closed-loop optimization does not need to be the first step.
DataPilot can bring thermal, power, equipment, operator and maintenance data into unified operational data. That alone makes it easier to understand where energy is being used, identify changes in equipment performance, and investigate shifts in PUE.
Maintenance Management can connect those signals directly to maintenance work. Predix can then surface changes, recurring issues and opportunities that would otherwise require someone to find them manually.
Once the data and operating behavior are understood, KoPilot closes the loop through a supervised deployment: one hall or one zone first, with people watching, then the rest.
Is your facility a good fit?
Five questions decide where you start.
- Do you have power and thermal data at sufficient resolution?
- Minute-level readings from the cooling plant and the IT load, not a monthly PUE.
- Can cooling equipment setpoints be adjusted through the existing control system?
- Chilled water and airflow setpoints have to be writable for the loop to close.
- Are airflow and containment issues understood well enough to separate equipment problems from control problems?
- A hot spot caused by a missing blanking plate is not a setpoint problem.
- Are operating constraints and safe limits clearly defined?
- Server inlet limits, equipment limits and the margin the site wants to keep.
- Is there an environment where new control strategies can be tested under supervision?
- A hall or a zone where a strategy can run with people watching before it runs alone.
What each product gives a facility like yours
Start with Maintenance Management or DataPilot. Predix needs both, and KoPilot adds control on top. Each product pays for itself on its own.
-
Start here
DataPilot
Inlet air temperature per rack, chilled water setpoints and CRAH performance in one place, so PUE stops being a number that arrives monthly and becomes something you can watch drift.
Your existing data logger never sees the operator's reading, and a maintenance system never sees the trend. Holding both makes everything to the right of the record possible. -
Start here
Maintenance Management
A chiller that begins short-cycling raises the job itself, carrying its own service history, and setpoint drift after a maintenance visit shows up the same week rather than next quarter.
The value is not the ticket, it is the work being done right: raised on real evidence, tracked, and closed against the machine that needed it, so time between failures rises and time to repair falls. A condition is more than a limit on one tag, and the examples on this page show what that buys. -
AI insights
Predix
A weekly account of where the controllable part of PUE went, including free cooling hours you did not take and the approach temperature you paid to hold, and what to change to take them.
Predix works on the unified operational data from DataPilot and Maintenance Management, measured against the targets you set. -
Autonomous control
KoPilot
Chilled water and airflow setpoints moved against real inlet temperatures rather than a commissioning margin nobody has revisited, inside limits written to protect the hardware.
Every setpoint passes through limits your engineers set for your site. The model cannot learn or change them, and your safety systems and interlocks stay in charge.
Why the control transfers
- 37%
- less air-handler fan energy from automatic fan-speed control, in a working colocation data center Lawrence Berkeley National Laboratory, 2012
- 2×
- winner of the Autonomous Greenhouse Challenge Greenhouse control, a different domain from this page
KoPilot’s control was proven in greenhouses, where the same physics of heat, air and water sets the limits, against expert growers on a live crop.
Every deployment starts read-only, on the data your facility already has. One hall or one zone goes first, with people watching, inside limits your team sets, and the building management system stays in charge of the equipment.
What we measure here
- CRAC and CRAH units
- inlet air temperature
- approach temperature
- delta-T across the rack
- chilled water setpoint
- hot and cold aisle containment
- free cooling hours
- PUE (power usage effectiveness)
See Koidra on your facility data
Bring a week of readings from one hall. We will show you what the platform sees, what it would have flagged, and what it would have scheduled.